Operational values
==================

.. admonition:: Command: post_models(*"r_flux_load","r"*)

 Returns the flux-linkage in an array with freely selectable identifier "r".

 **Example:**
 ::

  post_models("r_flux_load","r")
  Load_flux   = r[1]   -- Load flux [Vs]
  Noload_flux = r[2]   -- Noload flux [Vs]


.. admonition:: Command: post_models(*"r_load_voltage","r"*)

 Returns the voltage in an array with freely selectable identifier "r".

 **Example:**
 ::

  post_models("r_load_voltage","r")
  Load_voltage =   r[1]   -- Load_voltage [V]
  Noload_voltage=  r[2]   -- Noload_voltage [V]


.. admonition:: Command: post_models(*"r_current","r"*)

 Returns the current in a variable with freely selectable identifier "r".

 **Example:**
 ::

  post_models("r_current","r")
  current = r[1]   -- Current winding [A]


.. admonition:: Command: post_models(*"r_cosphi","r"*)

 Returns the power-factor in a variable with freely selectable identifier "r".

 **Example:**
 ::

  post_models("r_cosphi","r")
  cos_phi = r[1]    -- Power factor cos phi


.. admonition:: Command: post_models(*"r_beta_opt","r"*)

 Returns the current angle for maximum torque (I vs. Up, i.e. q-axis) in the variable with the freely selectable identifier "r".

 **Example:**
 ::

  post_models("r_beta_opt","r")
  angl_I_UPopt = r[1]   -- Load angle I vs. Up [Degr]

.. admonition:: Command: post_models(*"AV_DEMAGN","r"*)

 Returns parameters for assessing the magnetization or demagnetization state in the list with the freely selectable identifier "r".

 **Example:**
 ::

  post_models("AV_DEMAGN","r")
  av_demagn   = r[1]  -- Average Demagnization [kA/m]
  max_demagn  = r[2]  -- Maximum Demagnization [kA/m]
  area_demagn = r[3]  -- Relative Area of Demagnization [