Calculation Control Parameters¶
pre_models(“FE-contr-data”)
Definition of the basic parameters of the FE calculation and machine simulation.
Example and parameter description
m.hc_min = 95.0 -- Limit demagnetisa > 0:[%]Hc; <0 [kA/m]
m.con_hdcopy = 0 -- Hc-copy:Name:auto:0,intact:1, none:-1
m.b_max = 2.4 -- Max Induction [T] in colorgradation
m.b_min = 0 -- Move inside: 0 , Move outside: > 0
m.calc_fe_loss = 1 -- Calcul. FE-Loss > 0, areas <0, no (use FE-Losses Param = 2)
m.eval_force = 0 -- Eval. force density > 0, no <= 0
m.allow_draw = 1 -- Draw Graphics :> 0: yes, 0: no
m.fline_dens = 1 -- F-Lines: 1: small, 2: medium, 3:thick
m.num_flines = 10 -- Number of Field-lines: < 100 > 2
m.name_bch_log = 0 -- Name bch-file in Logfile:> 0:yes,0:no
m.st_size_move = 0.0 -- Step size move: r/ph:[degr], x/y:[mm]
m.num_nonl_it = 300 -- Max. nonlinear Iterations
m.perm_mode = 0 -- Permeability mode:>0:restore,0:actual
m.error_perm = 0.01 -- Rel. Permeability error [%]
m.allow_demagn = 0 -- Allow Demagnetisation:= 1:yes,= 0:no
m.maenergy = 0 -- Force from magn energy 1 :yes,= 0:no
m.el_order_ag = 1 -- El. order in air gap: lin=1: quadr=2
m.export_scrpt = 0 -- Export parameters in script: yes > 0
m.intern_bndc = 0 -- Intern. Boundary Conditions: yes > 0
pre_models("FE-contr-data")